Freescale Semiconductor /MK30D7 /TSI0 /GENCS

Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text

Interpret as GENCS

31 2827 2423 2019 1615 1211 87 43 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 (0)STPE 0 (0)STM 0 (0)ESOR 0 (0)ERIE 0 (0)TSIIE 0 (0)TSIEN 0 (SWTS)SWTS 0 (SCNIP)SCNIP 0 (0)OVRF 0 (0)EXTERF 0 (OUTRGF)OUTRGF 0 (EOSF)EOSF 0 (000)PS0 (00000)NSCN0 (0000)LPSCNITV 0 (0)LPCLKS

TSIEN=0, LPSCNITV=0000, PS=000, STPE=0, EXTERF=0, LPCLKS=0, ESOR=0, OVRF=0, ERIE=0, NSCN=00000, STM=0, TSIIE=0

Description

General Control and Status Register

Fields

STPE

no description available

0 (0): Disable TSI when MCU goes into low power modes.

1 (1): Allows TSI to continue running in all low power modes.

STM

Scan Trigger Mode. This bit-field can only be changed if the TSI module is disabled (TSIEN bit = 0).

0 (0): Software trigger scan.

1 (1): Periodical Scan.

ESOR

End-of-Scan or Out-of-Range Interrupt select

0 (0): Out-of-Range interrupt is allowed.

1 (1): End-of-Scan interrupt is allowed.

ERIE

Error Interrupt Enable

0 (0): Interrupt disabled for error.

1 (1): Interrupt enabled for error.

TSIIE

Touch Sensing Input Interrupt Module Enable

0 (0): Interrupt from TSI is disabled

1 (1): Interrupt from TSI is enabled

TSIEN

Touch Sensing Input Module Enable

0 (0): TSI module is disabled

1 (1): TSI module is enabled

SWTS

Software Trigger Start

SCNIP

Scan In Progress status

OVRF

Overrun error Flag. This flag is set when a scan trigger occurs while a scan is still in progress. Write “1”, when this flag is set, to clear it.

0 (0): No over run.

1 (1): Over Run occurred.

EXTERF

External Electrode error occurred

0 (0): No fault happend on TSI electrodes

1 (1): Short to VDD or VSS was detected on one or more electrodes.

OUTRGF

Out of Range Flag.

EOSF

End of Scan Flag.

PS

Electrode Oscillator prescaler. .

0 (000): Electrode Oscillator Frequency divided by 1

1 (001): Electrode Oscillator Frequency divided by 2

2 (010): Electrode Oscillator Frequency divided by 4

3 (011): Electrode Oscillator Frequency divided by 8

4 (100): Electrode Oscillator Frequency divided by 16

5 (101): Electrode Oscillator Frequency divided by 32

6 (110): Electrode Oscillator Frequency divided by 64

7 (111): Electrode Oscillator Frequency divided by 128

NSCN

Number of Consecutive Scans per Electrode electrode.

0 (00000): Once per electrode

1 (00001): Twice per electrode

2 (00010): 3 times per electrode

3 (00011): 4 times per electrode

4 (00100): 5 times per electrode

5 (00101): 6 times per electrode

6 (00110): 7 times per electrode

7 (00111): 8 times per electrode

8 (01000): 9 times per electrode

9 (01001): 10 times per electrode

10 (01010): 11 times per electrode

11 (01011): 12 times per electrode

12 (01100): 13 times per electrode

13 (01101): 14 times per electrode

14 (01110): 15 times per electrode

15 (01111): 16 times per electrode

16 (10000): 17 times per electrode

17 (10001): 18 times per electrode

18 (10010): 19 times per electrode

19 (10011): 20 times per electrode

20 (10100): 21 times per electrode

21 (10101): 22 times per electrode

22 (10110): 23 times per electrode

23 (10111): 24 times per electrode

24 (11000): 25 times per electrode

25 (11001): 26 times per electrode

26 (11010): 27 times per electrode

27 (11011): 28 times per electrode

28 (11100): 29 times per electrode

29 (11101): 30 times per electrode

30 (11110): 31 times per electrode

31 (11111): 32 times per electrode

LPSCNITV

TSI Low Power Mode Scan Interval.

0 (0000): 1 ms scan interval

1 (0001): 5 ms scan interval

2 (0010): 10 ms scan interval

3 (0011): 15 ms scan interval

4 (0100): 20 ms scan interval

5 (0101): 30 ms scan interval

6 (0110): 40 ms scan interval

7 (0111): 50 ms scan interval

8 (1000): 75 ms scan interval

9 (1001): 100 ms scan interval

10 (1010): 125 ms scan interval

11 (1011): 150 ms scan interval

12 (1100): 200 ms scan interval

13 (1101): 300 ms scan interval

14 (1110): 400 ms scan interval

15 (1111): 500 ms scan interval

LPCLKS

Low Power Mode Clock Source Selection.

0 (0): LPOCLK is selected to determine the scan period in low power mode

1 (1): VLPOSCCLK is selected to determine the scan period in low power mode

Links

() ()